Total line power adds shell emissivity weighted by volume. An image pixel adds that same emissivity along a sightline. Connecting the two integrals gives a practical test of whether an image really represents the calculated gas.
The saved state supplies ne and np in each shell. Atomic processes supply an effective coefficient γℓ for line ℓ. A coefficient in ergcm3s−1 already includes photon energy. Multiplying by the densities gives the angle-integrated energy emissivity ηℓ.
Emissivity has units ergcm−3s−1. A photon-number coefficient instead lacks the energy unit and needs one factor of hνℓ, where h is Planck’s constant and νℓ the photon frequency. Both conventions occur; the units tell you which coefficient you have.
For a prescribed effective model one can define photon yield pℓ=γℓ/(hνℓαB) per net radiative capture. Actual coefficients depend on atomic configuration, temperature and density. A display colour alone does not determine them.
ηℓ=γℓnenp,Lℓ=j∑ηℓ,jVj
Lℓ is total power into all directions, in ergs−1; Vj is the actual volume of shell j.
Assume isotropic emission and a line optically thin enough to escape without appreciable absorption or scattering. Divide the angle-integrated emissivity by 4π to obtain emission per solid angle, jℓ=ηℓ/(4π). This fixes the normalization between intensity and total power.
Let b be the projected distance from the centre and s the coordinate along a sightline. Intensity Iℓ(b) sums jℓ along that direction. Its units are ergcm−2s−1sr−1, distinct from the power of the whole cloud.
For a shell between radii rj−1 and rj, obtain its full two-sided path from right-triangle geometry: subtract the inner sphere’s chord from the outer sphere’s chord. A chord contribution vanishes when the impact parameter exceeds that sphere’s radius.
Iℓ(b)=∫4πηℓds
This is an optically thin snapshot projection with light-travel differences neglected. Display colours are a separate choice.
Δsj(b)=2[max(rj2−b2,0)−max(rj−12−b2,0)]
For uniform emissivity within a shell, multiply this path by its emission per solid angle and sum over shells.
Take a filled sphere of radius R and constant angle-integrated emissivity η. The path at b is 2R2−b2, longest through the centre and zero at the edge. This is a geometry reference with no enhanced emitting rim.
Now add the projected image. A thin annulus between b and b+db has area 2πbdb. Integrate intensity with that area weight and multiply by 4π to recover total power.
For the needed integral, substitute u=R2−b2 and du=−2bdb to obtain ∫0RbR2−b2db=R3/3. The final result is emissivity times sphere volume. Omitting annular area weights or adding an extra solid-angle factor fails this check.
I(b)=2πηR2−b2(0≤b≤R)
The figure uses our own analytic uniform sphere, not a real-nebula image or native Cloudy profile.
4π∫0RI(b)2πbdb=34πR3η=L
For a sufficiently distant source at D, the received total flux is F=L/(4πD2). The projected-area calculation gives the same result.Own uniform-sphere emissivity. The sightline curve and projected map use the same analytic path integral, with normalized intensity and explicit geometry. Open the full figure
For an explicit example, prescribe a red-line yield of 0.45 photons per net capture and vacuum wavelength 656.46nm. With light speed c and vacuum wavelength λ, use hν=hc/λ: each photon carries approximately 3.026×10−12erg. The yield is an input to this energy/geometry exercise, not a new atomic-transition calculation.
A steady cloud completely absorbing Q=1049s−1 has the same net recombination count, giving line power approximately 1.362×1037ergs−1. A photon count requires one photon-energy factor; an energy coefficient already contains it.
At 0.5trec in the ideal growing model, net recombinations are only 0.393469Q. Multiply the steady line power by that factor. Of an absorbed source supply, one portion increases the ion population and another replaces recombinations.
Two lines computed at a fixed prescribed temperature mainly reflect their chosen coefficients. Real red-to-blue hydrogen ratios can inform extinction studies, but those require an intrinsic ratio, a dust model and observational errors. Determining a new temperature would require additional independent information; here temperature is prescribed.
Carry an interval for gas outside coefficient support
Electron density may become very low outside a front or after switch-off. If a coefficient table has a lower density limit, clipping to that limit does not validate a new atomic state. Separate the resolved contribution from the part that is not determined.
Within an explicitly defined radiative-capture effective model, assign nonnegative Balmer yields with joint condition pα+pβ≤1. Use the specified interpolation inside support. Outside support, do not extrapolate a point coefficient; translate the allowed capture count into a positive line-energy upper bound.
Let supported emission sum to Lℓret and unsupported upper bounds to Uℓ. Then Lℓret≤Lℓ≤Lℓret+Uℓ. Refuse a scene if the omitted upper contribution is too large relative to retained power. Separate maxima for the two lines are generally not simultaneously attainable.
This controls omissions within that declared effective model. A complete statistical-equilibrium calculation with extra collisional or pumping sources needs its own argument. Images, powers and exports should carry the same emissivities and intervals; zero retained intensity need not mean proven zero light.
At fixed temperature, yields and Q, double the density of a fully absorbing uniform equilibrium cloud. How do total line power and central intensity change?
Read the explanation
Total net recombinations remain Q, so total line power is unchanged. Central intensity scales as nH2R and R∝nH−2/3; it rises by 24/3≃2.52. The same light is concentrated into a smaller projected area.
Retained line power is 1036ergs−1 and the unresolved upper contribution is 1033ergs−1. Give the range. Does it certify the complete Cloudy atomic model?
Read the explanation
Within the stated effective model, the range is [1036,1.001×1036]ergs−1, an omitted upper fraction of one part in a thousand. It does not certify a different atomic model containing additional physical source terms.
Fixed inspected lecture PDF: III-2, III-7/8 and III-37/38. Ionization balance, Case B, recombination scales and line counting. Our nucleus/electron/particle definitions are explicit. No lecture pages or figures are redistributed.
Original hydrogenic recombination-line calculations distinguish energy emissivities, effective coefficients and their atomic assumptions. No native coefficient table is included. The worked line-yield example prescribes its own illustrative input.
The native equilibrium runs pin this Cloudy release. They use uniform hydrogen at fixed temperature, a prescribed stellar spectrum and an on-the-spot treatment of recombination radiation. The teaching calculation prescribes its own constant recombination coefficient.
MIT-licensed Python recomputes ideal scales, growth, local recombination, projection and synthetic filtering. The generic shell integrator reads radius and emissivity files from locally saved runs.
Keep reading
What this page links to directly
You are hereAdding hydrogen-line light along a sightline