How do currents divide at junctions and around loops?
Use charge and energy conservation to solve a circuit with two loops. See how a real meter changes a branch current or voltage.
Before you start: Chapter 2 on potential difference and Volume 1 Chapter 9 on work and power. This chapter uses simultaneous equations.
After this chapter you can: Write the junction and loop equations for a steady circuit, check its power balance and calculate the effect of connecting a meter.
At a junction in a steady circuit, as much charge leaves each second as enters. Around a closed loop, the changes in voltage add to zero. Use these two rules with the resistance of each branch to find the currents. A meter can change those currents because connecting it adds a path or a resistance to the circuit.
Chapter 2 related voltage to energy per unit charge. Volume 1, Chapter 9, used power to track energy transferred per second. This chapter uses those ideas to solve a two-loop circuit and to calculate what changes when a meter is connected.
3.1 A resistor connects voltage drop, current and power
Current I=dQ/dt is the signed rate at which charge Q crosses a section of wire. Choose a reference direction when you label a branch. A positive current means positive charge flows in that direction, or negative charge flows the other way. The unit is the ampere, one coulomb per second.
For an ohmic resistor of constant resistance R, choose the current reference from terminal a to b. Write their voltages as Va and Vb, measured in volts relative to the same reference node. Ohm's law and the power absorbed by the resistor give
Va−Vb=IR,P=(Va−Vb)I=I2R.
Resistance is measured in ohms, one volt per ampere. A positive current in the chosen direction goes from higher to lower potential through the resistor. The voltage drop gives the energy lost per unit positive charge. Multiplying by the charge per second gives the rate of heating, in watts. If the current reverses, both the voltage drop and the current change sign. The resistor still absorbs power. OpenStax, University Physics Volume 2, Section 9.3, electrical energy and power.
3.2 Junctions conserve charge and loops balance voltage
Treat an ideal wire as holding the same potential all along its length. Connected pieces of ideal wire at a common potential form a node. At a junction, take each labelled current as entering or leaving according to its reference arrow. The algebraic difference of entering and leaving currents gives the rate of charge accumulation. In steady direct current, the rate vanishes.
∑Iin=∑Iout.
Choose either direction around a closed loop. Count a rise when you cross an ideal voltage source from its negative terminal to its positive terminal. When you cross a resistor along its reference arrow, write −IR for the change in voltage. Reverse either traversal and the sign reverses. Once you come back to the starting point, its potential is unchanged, so
loop∑ΔV=0.
These are Kirchhoff's junction and loop rules. The loop rule here uses a steady circuit with no changing magnetic flux through the loop. Analytically you can set any one node to zero volts. Adding the same constant to every node voltage preserves all the differences and currents. OpenStax, University Physics Volume 2, Section 10.3.
3.3 Series shares one current and parallel shares one voltage
Two resistors in series meet at a junction with no other branch. The junction rule gives both the same current. Their voltage drops add, so the pair has the same terminal response as one resistor with Rseries=R1+R2.
Two resistors in parallel are connected between the same two nodes. Each has the same voltage drop. Their currents add, so the pair has the equivalent resistance
Rparallel1=R11+R21.
Two equal resistors in parallel give half the resistance of one. At a fixed terminal voltage, the second branch carries a second copy of the first current. Check which nodes a resistor connects before deciding whether that rule applies. OpenStax, University Physics Volume 2, Section 10.2.
3.4 A two-loop calculation finds direction as well as magnitude
Put ideal sources of 12V and 6V on the left and right. Join both negative terminals to the zero-volt return. Connect the left positive terminal to junction J through RL=2kΩ and the right positive terminal through RR=3kΩ. The junction connects back to the return through RC=6kΩ. Label currents IL and IR toward J from the two sources, and IC down through the shared resistor.
Figure 3.1 An ideal two-loop circuit. The two sources share the bottom return, chosen as zero volts. The arrows mark the reference directions used to write the equations.
For each loop, start at the return and go up through the source, toward J through its resistor, then down through the shared resistor. The loop equations and junction rule give
The shared resistor has drop VJ=ICRC. Put this junction voltage into the first two equations and substitute the resulting branch currents in the third.
2kΩ12V−VJ+3kΩ6V−VJ=6kΩVJ.
This gives VJ=8V, IL=2mA, IR=−32mA and IC=34mA. The right current is negative because J sits above the right source in potential. The current on that branch goes from J into the positive terminal of the right source.
Check energy per second as well as charge per second. The left source delivers 24mW. The right source absorbs 4mW because current enters its positive terminal. The three resistors together absorb 20mW by the sum of their I2R terms. This is an ideal calculation with fixed source voltages.
3.5 Connecting a meter changes the circuit it measures
Open Moving-Coil Meter and DC Multimeter and choose Reset. The simulated board routes the source through its internal resistance to a feed post. A closed bridge connects the feed post to the load post. The load resistor connects the load post to the return. For the default voltage measurement the red probe is on the load and the black probe is on the return. The meter measures red minus black. Its input is a second branch across the load. OpenStax, University Physics Volume 2, Section 10.4.
The source is 10V, with both resistances set to 200kΩ. Without the meter the two resistances share the source voltage equally. The moving-coil voltage input is also 200kΩ, from its coil and a series range resistor. It halves the effective load resistance to 100kΩ, leaving the load at one third of the source voltage. Predict the effect of raising the input resistance. Now choose Digital, with finite input. The 10MΩ input draws less current and the load voltage comes closer to its original value.
Next choose A sensitive current range, followed by Less current burden. Both presets set the source to 1.00V with no internal resistance and a load of 1.00kΩ. The bridge opens, and the red and black probes connect to feed and load, respectively. The meter now completes the only path to the load. Inside the moving-coil meter, a parallel shunt carries most of the current. From outside, the entire meter adds 100Ω in series on the lower range and 10Ω on the higher range. The magnitude of the voltage across its terminals, called the burden voltage, falls from about 90.9mV to 9.90mV between these presets.
Table 3.1 Readings from Reset followed by those three presets in order. The first two numbers in each row come from the circuit model. The reference uses the closed bridge with the meter absent. The connected value describes the circuit after the meter is in place. The saved indication comes from the simulated coil angle or digital counts after calibration.
Setting
Before connection
After connection, steady
Saved indication
Reset, moving-coil voltage (V)
5.000
3.333
3.333
Digital voltage (V)
5.000
4.950
4.950
Lower current range (mA)
1.000
0.9091
0.9091
Higher current range (mA)
1.000
0.9901
0.9909
The preset records include noise. The digital record also includes rounding to counts. The small difference between the higher-range connected current and the saved indication comes from the simulated observation and calibration. The larger difference from the no-meter reference comes from adding the meter's resistance. Use the JSON export to find the raw and calibrated quantities for each setup.
3.6 Exercises
A steady conventional current of 0.30A passes through a metal wire for 8.0s. How much charge passes a fixed section? In which direction do the electrons drift relative to the current?
A 120Ω resistor has 6.0V across it. Find its current magnitude and power dissipation.
A branch carries 5.0mA into a junction. A second branch carries 2.0mA out. What current must a third branch carry, and in which direction?
Compare a 2.0kΩ resistor and a 6.0kΩ resistor in series and in parallel. Find the equivalent resistance in each case.
In Figure 3.1 replace only the right source with an ideal 12V source with its positive terminal still at the top. Find the junction voltage and the direction of the right-branch current.
What does the negative right-branch current in the original example tell you about the energy transfer at the right source? Calculate its power.
In the default voltage-divider setup, suppose the voltmeter input resistance tends to infinity. What happens to the voltage and meter current? Explain using the junction.
In the current-measurement setup, keep the bridge closed with probes still across feed and load. In the steady model, what voltage is across the meter and what current passes through it? Explain whether it reads the load current.
3.7 Answers and explanations
Exercise 1Show the answer
The charge magnitude is IΔt=2.4C. Electrons are negative, so they drift opposite to the conventional current.
Exercise 2Show the answer
Ohm's law gives I=(6.0V)/(120Ω)=0.050A. The resistor absorbs P=(6.0V)(0.050A)=0.30W.
Exercise 3Show the answer
The third branch carries 3.0mA out. The junction has no accumulating charge, so the two outgoing currents must add to the incoming current.
Exercise 4Show the answer
The series resistance is 8.0kΩ because each resistor contributes a drop at the same current. The parallel equivalent is 1.5kΩ because the conductances, the reciprocals of resistance, add at the same voltage.
Exercise 5Show the answer
The incoming current is (12V−VJ)(1/RL+1/RR). Set it equal to the current down through the shared resistor to get VJ=10V. The right-branch current now points from the right source toward J, since the source node is at the higher potential.
Exercise 6Show the answer
The current enters the positive terminal of the right source. The source absorbs (6V)(32mA)=4mW.
Exercise 7Show the answer
The meter current goes to zero. At the junction the source current then goes entirely through the load. The load and source resistance form the original equal-resistance divider, so the load voltage approaches 5.0V.
Exercise 8Show the answer
The closed ideal bridge makes feed and load the same node. The meter terminal voltage is zero, and so is the current through the meter at steady state. The bridge provides the path for the load current. The meter indication therefore misses the load current.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.