Skip to main content
Sandbox Physics

B-X3 · Time from electron spectra

Attosecond RABBIT Metrology

How can electron spectra reveal the duration of an attosecond pulse train? The delay-dependent electron sidebands reveal phase differences between neighboring harmonics. Combine those phases with calibrated harmonic strengths to recover the pulse train; the atom’s contribution must be accounted for.

Scan the delay between ultraviolet harmonics and an infrared probe. Fit the sidebands in the recorded electron counts, correct a declared atomic phase and reconstruct the light pulses.

Interactive modelAttosecond RABBIT Metrology

Drag the teal carriage or move the delay below. Both infrared passes lengthen together.

Physical mirror travel

Δx=0.000 μm\Delta x=0.000\,\mu\mathrm m

Probe delay

τ=0.00 fs\tau=0.00\,\mathrm{fs}

Carriage travel is magnified eighty thousand times; particle motion is shown in slow motion.

Apparatus scale and particle motion

The carriage travel is magnified eighty thousand times. Light and electron markers move slowly to show the route; they are not individual recorded events. The analyzer is shown cut open.

Measurement sequence

Scan the delay. Recover the pulse.

The carriage advances through sixty-four delays. Every setting adds an electron energy spectrum to the same acquisition.

  1. 01Set the instrument
  2. 02Record the scan
  3. 03Infer from counts

Ready. Choose a setup, then start the scan.

Start a scan to record counts. The spectrum will appear here as measurements arrive.

Recorded counts

Electron energy against delay

No acquisition yet

τ/fs,Ee/eV\tau/\mathrm{fs},\quad E_e/\mathrm{eV}

Click the image to move the delay probe. Color shows square-root counts; the CSV retains linear counts.

Test the measurement model

Each sideband carries a phase

τ/fs,NSB\tau/\mathrm{fs},\quad N_{\rm SB}

Choose a sideband. Dots are sums from its recorded energy window; the curve fits those sums.

From relative phase to time

Reconstruct one period of the train

t/fs,I/Imax⁡t/\mathrm{fs},\quad I/I_{\max}

Teal: reconstruction from fitted phases and calibrated amplitudes. Gold dashed: separate source reference. Satellites can remain outside the main peak.

Recovered adjacent phase differences
S12S_{12}
—\text{—}
S14S_{14}
—\text{—}
S16S_{16}
—\text{—}
S18S_{18}
—\text{—}

Physics tutorial

Attosecond RABBIT Metrology

BackgroundScan the delay between ultraviolet harmonics and an infrared probe. Fit the sidebands in the recorded electron counts, correct a declared atomic phase and reconstruct the light pulses.

Why it mattersA broad spectrum can produce pulses of different duration. Measuring the relative phase tells us how its frequencies combine in time.

Start with the essentials

Focus question
How can electron spectra reveal the duration of an attosecond pulse train?
One-sentence intuition
The timing comes from the phase of a measured electron oscillation and a model of the atom.

Core mathematical model

Two paths to the same sideband

Sj(τ)=Aj+Bjcos⁡[2ωτ−Δϕj−θj]S_j(\tau)=A_j+B_j\cos[2\omega\tau-\Delta\phi_j-\theta_j]

The neighboring-harmonic phase difference and the atomic phase both shift the twice-infrared oscillation. Positive delay means that the infrared probe arrives later.

Reconstruct from the fitted phases

I(t)=∣∑jaje−iqjωt+iϕ^j∣2I(t)=\left|\sum_j a_j e^{-iq_j\omega t+i\widehat\phi_j}\right|^2

The amplitudes are known calibration inputs. Relative phases are accumulated from the fitted sidebands after the chosen atomic correction. The absolute field phase is arbitrary.

Common difficulties

A reconstructed result depends on the measurement model

Typical misconceptionThe measured phase is entirely the light pulse’s phase.

Better mental modelThe atom adds a phase to the two-path signal. The correction here is a stated external input; real atomic calculations require more physics.

Run the experiment

  1. 01

    Record the sidebands

    Choose Phase-locked train, acquire and analyze the counts.

    What to observe: The energy–delay image contains oscillating sidebands. The fitted phases produce a short recurring burst.
  2. 02

    Keep the same data, change the correction

    Choose Atomic-phase error, acquire and analyze, then switch on the atomic correction.

    What to observe: The count image is unchanged. The recovered phase curvature and pulse width change.
  3. 03

    Lower the counts

    Choose Few counts and compare repeated acquisitions.

    What to observe: Shot noise changes the fitted phase. The duration is withheld when the oscillation is too weak.
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy