---
title: "Double-slit interference and diffraction | Sandbox Physics"
description: "Calculate where two paths reinforce or cancel, then use slit width and coherence to explain missing or faded fringes."
canonical_url: "https://sandboxphysics.com/learn/light-and-imaging/two-path-interference/"
language: "en"
page_type: "story"
alternate_languages:
  zh-CN: "https://sandboxphysics.com/zh/learn/light-and-imaging/two-path-interference/"
last_modified: "2026-11-24"
---

[Volume 4 · Light, Imaging and Measurement](https://sandboxphysics.com/learn/light-and-imaging/)

# How do two paths produce bright and dark fringes?

Calculate where two paths reinforce or cancel, then use slit width and coherence to explain missing or faded fringes.

Before you start: [Chapter 1](https://sandboxphysics.com/learn/light-and-imaging/reflection-and-refraction/) on optical paths. [Volume 2 Chapter 5](https://sandboxphysics.com/learn/oscillations-and-waves/travelling-waves/) and [Chapter 6](https://sandboxphysics.com/learn/oscillations-and-waves/standing-waves-and-fourier/) on phase and superposition.

After this chapter you can: Predict fringe positions, check for missing orders and use the fringe contrast to compare coherence.

At the screen, two light fields add. If the waves arrive in step, the combined field is larger. If equal fields arrive half a cycle apart, they cancel. Moving across the screen changes the path difference and repeats this pattern. Wide slits also set a broad envelope that can erase some of the bright orders.

Volume 2, Chapters 5 and 6, tracked phase along a path and added waves. Chapter 1 of this volume related wavelength to refractive index. Here we connect those ideas to the spacing, envelope and contrast of a double-slit pattern.

## 3.1 Optical path sets the phase at the detector

Light of vacuum wavelength $\lambda_0$ gains phase at a rate of $2\pi n/\lambda_0$ radians per metre in a material of refractive index $n$. The optical path is the sum of each segment's length times its index. Let $\Delta\mathcal L$ be the second optical path minus the first, and let $\phi$ be the initial phase of the second wave minus that of the first. At the detector their phase difference is

$$
\delta=\phi+\frac{2\pi}{\lambda_0}\Delta\mathcal L .
$$

For two coherent waves of the same frequency and polarization, let $I_1$ and $I_2$ be the intensities they would give separately. Adding the fields and taking the time average of their square gives

$$
I=I_1+I_2+2\sqrt{I_1I_2}\cos\delta .
$$

The last term comes from the product of the two fields. With equal amplitudes it takes the combined intensity from zero at a half-cycle difference to four times one wave's intensity when they are in phase. These are local detector intensities. The bright and dark regions redistribute light across the pattern. [OpenStax, University Physics Volume 3, Section 3.2](https://openstax.org/books/university-physics-volume-3/pages/3-2-mathematics-of-interference).

Open [Coherent Wave Composer](https://sandboxphysics.com/labs/coherent-wave-composer/) and choose **Two-wave fringes**. Leave two equal, same-frequency waves and the probe at $x_p=0$. Change the extra optical path between adjacent waves from zero to $0.25\lambda_0$, then to $0.50\lambda_0$. The detector value relative to one wave goes from $4$ to $2$ to $0$. The model uses a squared electric-field amplitude for a scalar detector. Its pattern lets you test the phase change without inferring absolute power from the wave display.

## 3.2 Slit separation sets the phase-order spacing

Put two slit centers a distance $d$ apart and a screen a distance $L$ away. Label the screen coordinate $y$ from the center, increasing toward the right slit. When $y$ and slit separation are both small compared with $L$, the right path minus the left path is approximately $-dy/L$. The path difference is negative on the right because that slit is closer to the point.

Let $\lambda$ be the wavelength in the material between the slits and screen. Start with both slits in phase. The arriving phases align again whenever their difference is a whole number of cycles. With integer order $m$, the aligned positions and their spacing are

$$
y_m=m\frac{\lambda L}{d},\qquad
\Delta y=\frac{\lambda L}{d}.
$$

Halfway between two aligned positions is a half-cycle difference. Equal coherent contributions cancel there. A larger separation makes the phase change faster across the screen, so the fringes are closer. A longer wavelength, or a more distant screen at the same angle, spreads the pattern. [OpenStax, University Physics Volume 3, Section 3.1](https://openstax.org/books/university-physics-volume-3/pages/3-1-youngs-double-slit-interference).

## 3.3 Slit width sets the broad envelope

Now let each slit have width $a$. Points across one slit contribute different phases. In the scalar far-field approximation, a point displaced by $u$ from a slit center contributes a phase shift of $-2\pi uy/(\lambda L)$. For uniform illumination, opposite points cancel the sine contributions. Average the cosine across the width to get the field from one slit relative to its on-axis value.

$$
\begin{aligned}
\frac{1}{a}\int_{-a/2}^{a/2}\cos\left(\frac{2\pi u y}{\lambda L}\right)\mathrm du
&=\operatorname{sinc}\left(\frac{\pi a y}{\lambda L}\right),\\
\operatorname{sinc}(z)&=\frac{\sin z}{z},\quad \operatorname{sinc}(0)=1 .
\end{aligned}
$$

Squaring gives the single-slit intensity envelope. It reaches its first zeros at $y=\pm\lambda L/a$. Both slits have this same envelope when they have equal widths. Combining it with the two-path interference factor for equal, in-phase sources gives

$$
\frac{I(y)}{I_{\mathrm{ref}}}=
\operatorname{sinc}^2\left(\frac{\pi a y}{\lambda L}\right)
\cos^2\left(\frac{\pi d y}{\lambda L}\right).
$$

The reference $I_{\mathrm{ref}}$ is the on-axis intensity of equal, fully coherent slits at the current geometry. Increasing the width brings the first envelope zero inward without changing the phase-order spacing. If $d/a=3$, the third aligned position on each side lies at the first envelope zero, so order three is missing. Exact maxima of the product can shift away from their phase-alignment positions because the envelope itself varies. [OpenStax, University Physics Volume 3, Section 4.2](https://openstax.org/books/university-physics-volume-3/pages/4-2-intensity-in-single-slit-diffraction), [double-slit diffraction](https://openstax.org/books/university-physics-volume-3/pages/4-3-double-slit-diffraction).

- Screen intensity
- Upper envelope
- Missing phase order

**Figure 3.1** Calculated pattern for equal, in-phase slits with a separation of 180 micrometres and a width of 60 micrometres. The wavelength is 532 nanometres and the screen is 1.50 metres away. The envelope reaches zero at the two aligned third-order positions. Screen position is in millimetres.

## 3.4 Phase stability determines fringe contrast

If the relative phase fluctuates during a reading, the time average of the interference term shrinks. The double-slit Lab represents this by multiplying that term by a real mutual coherence factor $\mu$ between zero and one. It keeps the individual slit intensities fixed. For equal amplitudes at one screen point away from an envelope zero, scan the relative phase and measure maximum and minimum intensities. The phase-scan visibility is

$$
V=\frac{I_{\max}-I_{\min}}{I_{\max}+I_{\min}}=\mu .
$$

The visibility above compares a phase scan at the same position. Across the screen, the changing envelope can affect a peak and its neighbor by different amounts. An actual instrument can use contrast to infer something about the light source. At SPEAR3, a double-slit interferometer used measurements at several slit separations to infer the particle beam size from the spatial coherence of its emitted light. [Li et al., Double-Slit Interferometer Measurements at SPEAR3](https://arxiv.org/abs/1911.04573).

Open [Young Double-Slit Bench](https://sandboxphysics.com/labs/young-double-slit-bench/) and choose **Narrow-slit interference**. The wavelength is $532\,\mathrm{nm}$, the slit separation is $180\,\mathrm{\mu m}$ and the screen distance is $1.50\,\mathrm m$. Read the intensity at a shared screen probe position of $13.30\,\mathrm{mm}$. Choose **Every third order missing** and set the probe back to that same position for comparison. Then return to the narrow-slit preset. Change only **Mutual coherence between slits** from one to $0.25$. Check how the center intensity and the phase-scan visibility change.

**Table 3.1** Values from the simulated double-slit model. Intensities use the fully coherent on-axis reference for each geometry. Phase-scan visibility describes the contrast at points with a nonzero envelope.

| Slit width (µm) | Mutual coherence | Phase-order spacing (mm) | First envelope zero (mm) | Intensity at 13.30 mm | Phase-scan visibility |
| --- | --- | --- | --- | --- | --- |
| 20 | 1.00 | 4.433 | 39.900 | 0.684 | 1.000 |
| 60 | 1.00 | 4.433 | 13.300 | 0.000 | 1.000 |
| 20 | 0.25 | 4.433 | 39.900 | 0.427 | 0.250 |

The center intensity in the last row is $0.625$, down from one. At the first nominal dark position, a probe at $2.22\,\mathrm{mm}$ rises from nearly zero to about $0.371$. The fringes lose contrast because the interference term shrinks. Changing the slit width can move an envelope zero instead. The model uses two disjoint, infinitely tall slits and ideal detection in the paraxial far field. The calculation keeps only the part of aperture phase that varies linearly across a slit.

## 3.5 Exercises

1. Two equal coherent fields traverse paths whose optical lengths differ by $\lambda_0/2$. Their initial phases match. What intensity do they produce at the detector?
2. Put a plate of thickness $1.00\,\mathrm{\mu m}$ and index $1.30$ into one path, replacing the same thickness of air of index one. Neglect reflections. For $\lambda_0=600\,\mathrm{nm}$, how much phase does it add?
3. Two slits separated by $0.250\,\mathrm{mm}$ send light of wavelength $500\,\mathrm{nm}$ to a screen $2.00\,\mathrm m$ away. Find the phase-order spacing.
4. Keeping all else fixed, halve the slit width. What happens to the first envelope zero and the phase-order spacing?
5. Suppose $d/a=4$ and the slits start in phase. Which aligned orders coincide with the first and second positive envelope zeros?
6. At a fixed point two fully coherent fields have intensities $I_1=4$ and $I_2=1$ in the same units. Find the maximum and minimum combined intensities as relative phase changes. Can the spot go completely dark?
7. In the equal-amplitude Lab model at a fixed screen point, the relative phase is scanned and gives maximum and minimum intensities of $0.75$ and $0.25$. What is the mutual coherence factor?
8. A technician sees a dark feature in an equal-amplitude double-slit pattern. How could reducing the mutual coherence tell whether that point was an envelope zero or a cancellation between the two slits?

## 3.6 Answers and explanations

Exercise 1

The path difference gives phase $\pi$. Equal field amplitudes point in opposite phase, so the field sum vanishes and the intensity is zero.

Exercise 2

Replacing air adds optical path $(1.30-1.00)(1.00\,\mathrm{\mu m})=0.300\,\mathrm{\mu m}$. That is half the vacuum wavelength, so the phase increases by $\pi$ radians.

Exercise 3

The spacing is $\lambda L/d=4.00\,\mathrm{mm}$. Moving by that distance changes the phase difference by one full cycle.

Exercise 4

The first zero moves twice as far from the center because its distance is proportional to the reciprocal of the width. The phase-order spacing stays the same because the distance between slit centers is fixed.

Exercise 5

The first envelope zero is at $\lambda L/a$, four times the phase-order spacing. It removes order four. The second zero is twice as far out and removes order eight.

Exercise 6

The field amplitudes are proportional to two and one. Add them in phase to get intensity $(2+1)^2=9$ and subtract them at opposite phase to get $(2-1)^2=1$. The smaller field is too weak to cancel the larger one.

Exercise 7

The visibility is $(0.75-0.25)/(0.75+0.25)=0.50$. For equal slit amplitudes at the same point, the coherence factor equals this visibility.

Exercise 8

Reducing coherence weakens cancellation between the slits, so an interference minimum with nonzero envelope fills in. At an envelope zero each slit already contributes zero field there, so weakening their mutual coherence leaves the intensity at zero.

## Test it in the Lab

Change one setting at a time, then compare what you see with the tables and answers in this chapter.

[Young Double-Slit Bench → Separate diffraction from interference on a 3D double-slit bench, then measure missing orders, the effect of partial coherence and the contrast when the two amplitudes differ.](https://sandboxphysics.com/labs/young-double-slit-bench/) [Coherent Wave Composer → A live landscape of the signed field, complex phasor polygons and two detector traces all come from one deterministic sum of plane waves. Combine two to six waves, move the probe, shift phase and optical path, and reveal beats through a finite detector window.](https://sandboxphysics.com/labs/coherent-wave-composer/)

## Sources and reading scope

1. [OpenStax, University Physics Volume 3, §3.1 Young’s Double-Slit Interference](https://openstax.org/books/university-physics-volume-3/pages/3-1-youngs-double-slit-interference)

   The section derives the path difference at an observation angle and identifies constructive and destructive interference.

2. [OpenStax, University Physics Volume 3, §3.2 Mathematics of Interference](https://openstax.org/books/university-physics-volume-3/pages/3-2-mathematics-of-interference)

   The section relates sinusoidal phase differences to intensity and fringe positions.

3. [OpenStax, University Physics Volume 3, §4.2 Intensity in Single-Slit Diffraction](https://openstax.org/books/university-physics-volume-3/pages/4-2-intensity-in-single-slit-diffraction)

   The section adds field contributions across a finite slit and derives the intensity envelope and its zeros.

4. [OpenStax, University Physics Volume 3, §4.3 Double-Slit Diffraction](https://openstax.org/books/university-physics-volume-3/pages/4-3-double-slit-diffraction)

   The double-slit examples show interference fringes under a diffraction envelope and identify missing orders.

5. [Chunlei Li et al., Double-Slit Interferometer Measurements at SPEAR3](https://arxiv.org/abs/1911.04573)

   The instrument measures fringe contrast as the slit separation varies, then infers accelerator beam size from spatial coherence.

[← Chapter 2 · How does a lens form an image?](https://sandboxphysics.com/learn/light-and-imaging/thin-lenses-and-imaging/) [Chapter 4 · What sets the finest detail an optical system can resolve? →](https://sandboxphysics.com/learn/light-and-imaging/diffraction-and-resolution/)

Chapters in this volume

- [1. Where does light go at an interface?](https://sandboxphysics.com/learn/light-and-imaging/reflection-and-refraction/)
- [2. How does a lens form an image?](https://sandboxphysics.com/learn/light-and-imaging/thin-lenses-and-imaging/)
- [3. How do two paths produce bright and dark fringes?](https://sandboxphysics.com/learn/light-and-imaging/two-path-interference/)
- [4. What sets the finest detail an optical system can resolve?](https://sandboxphysics.com/learn/light-and-imaging/diffraction-and-resolution/)
- [5. How does a detector measure polarization?](https://sandboxphysics.com/learn/light-and-imaging/measuring-polarization/)
- [6. How do gain and feedback make a laser oscillate?](https://sandboxphysics.com/learn/light-and-imaging/laser-gain-and-cavity-modes/)

## Keep reading

Interactive Physics Textbook · Reading path

### Light, Imaging and Measurement

1. [Article **Where does light go at an interface?**](https://sandboxphysics.com/learn/light-and-imaging/reflection-and-refraction/)
2. [Article **How does a lens form an image?**](https://sandboxphysics.com/learn/light-and-imaging/thin-lenses-and-imaging/)
3. [You are here **How do two paths produce bright and dark fringes?**](https://sandboxphysics.com/learn/light-and-imaging/two-path-interference/)
4. [Article **What sets the finest detail an optical system can resolve?**](https://sandboxphysics.com/learn/light-and-imaging/diffraction-and-resolution/)
5. [Article **How does a detector measure polarization?**](https://sandboxphysics.com/learn/light-and-imaging/measuring-polarization/)
6. [Article **How do gain and feedback make a laser oscillate?**](https://sandboxphysics.com/learn/light-and-imaging/laser-gain-and-cavity-modes/)
