title: "Two flashes in a dual-phase xenon TPC Interactive Lab | Sandbox Physics"
description: "How do two flashes locate an energy deposit? The first flash marks the energy deposit."
canonical_url: "https://sandboxphysics.com/labs/dual-phase-xenon-tpc/"
language: "en"
page_type: "lab"
alternate_languages:
  zh-CN: "https://sandboxphysics.com/zh/labs/dual-phase-xenon-tpc/"
last_modified: "2026-11-23"
---

# Two flashes in a dual-phase xenon TPC

**How do two flashes locate an energy deposit?** The first flash marks the energy deposit. Electrons then drift into gas and produce a second flash. Their time separation gives depth after drift-speed calibration, and the upper light pattern helps locate the deposit sideways.

Follow electrons from liquid xenon into gas, compare the timing and light patterns, and use independent standards to estimate position and visible energy.

> Interactive simulation: open this page in a web browser to change the parameters and run the model.

Prepare a model interaction

Horizontal X $0\,\mathrm{cm}$ Horizontal Y $0\,\mathrm{cm}$ Depth below surface $15\,\mathrm{cm}$ Visible energy $5\,\mathrm{keVee}$ Light–charge partition Electron lifetime setting

Input changes apply to the next acquisition.

Acquisition settings and independent standards

A new lifetime setting requires its own detector preparation and calibration. The independent standards retain their issued dates.

Model assumptions

Point deposits, vertical drift and supplied light/charge partition statistics. Light travels isotropically along straight paths. Refraction, reflections, scattering, diffusion and real field distortions are omitted. Ideal counters include dark counts and double-photoelectron emission. Parameters and standards are teaching inputs. Position and visible quantum energy are conditional points, without unknown-event confidence regions, dark-matter identification or total nuclear-recoil energy.

## Locate an energy deposit from two flashes

**Background** An energy deposit leaves light and free electrons in liquid xenon. Prompt light forms S1. Electrons drift upward, enter the gas and gain energy from the electric field. Their excitation of xenon produces S2, making a small charge easier to read.

**Why it matters** A deeper deposit gives electrons a longer journey. An uneven upper light pattern provides another clue. Calibrated timing and light collection turn these clues into position.

- **Focus question**: What happens to the second flash when the deposit is deeper?
- **One-sentence intuition**: Drift time provides depth and the S2 pattern provides transverse position, after accounting for the detector response.

### Core mathematical model

#### Liquid drift time determines height

$$
z=z_g-v_d t_{\mathrm{bulk}}
$$

Height is zero at the liquid surface and positive upward. The gate lies below the surface; calibration supplies the liquid drift speed. Separate terminal transport, gas-light timing and the mean prompt delay from the difference of the two measured centroids. The mean gas-light delay also depends on the transverse candidate position.

#### The field pays for gas scintillation

$$
N_{\gamma,\mathrm{EL}}\frac{hc}{\lambda}\leq N_{\mathrm{ext}}eV_g
$$

Extracted electrons gain electrical work across the gas voltage. Part becomes ultraviolet photons, whose energy is Planck’s constant times light speed divided by wavelength. Other energy remains in unobserved channels. Emitted photons differ from detected photoelectrons; one vacuum-ultraviolet photon can release two photoelectrons.

### Common difficulties

#### Does more gas light mean a larger original deposit?

**Typical misconception** All S2 light energy came from the initial particle.

**Better mental model** Electrons obtain additional energy from the gas electric field. Calibration converts the amplified light signal back to charge before drift.

#### Does an NR-like record identify dark matter?

**Typical misconception** A nuclear-recoil-like light-to-charge ratio identifies a dark-matter particle.

**Better mental model** Recoil populations fluctuate, overlap and have backgrounds. This exercise compares two supplied partitions at a given visible energy, without event-class probabilities or total nuclear-recoil energy.

### Run the experiment

1. 01

   #### Separate prompt light from drifting charge

   Choose Central event, switch between the cutaway and surface views, and inspect the receiving curves.

   **What to observe:** The early narrow signal is S1; gas produces the later S2. The apparatus replays declared inputs. The curves retain the actual simulated counts in this exposure’s bins.

2. 02

   #### Compare shallow and deep deposits

   Choose Near surface, then Deep event. Each preset acquires a record; switch between the saved records to compare them.

   **What to observe:** A longer liquid path delays S2. Independent interval and electron-injection standards help separate the clock scale and terminal transport delay.

3. 03

   #### Move the deposit sideways

   Drag the transverse handle inside the liquid and acquire, or choose Bright off-centre.

   **What to observe:** The four upper fractions change. The search evaluates all 625 supplied cells. Its best cell is a conditional point; an engineering score is not confidence.

4. 04

   #### Watch charge loss during drift

   Choose Short electron lifetime and compare with ordinary purity at a similar depth.

   **What to observe:** Attachment reduces the electrons reaching gas and accumulates along the drift. Energy estimation must account for collection, extraction and attachment.

5. 05

   #### Change selection after saving the counts

   Open the extra settings, change the S1 threshold, and inspect the complete cell table and export.

   **What to observe:** Selection marks existing exposures. Counts, cell scores and point estimates remain unchanged. Zeros and saturation flags survive; animation supplies no missing clock or calibration.

Physical conclusion

Identify the two flashes, then interpret them with independent time, position and response standards. Small signals and incomplete calibration limit the estimates.

Sources and detector references

- [XENON Collaboration · Time Projection Chamber](https://xenonexperiment.org/time-projection-chamber/)
- [The XENONnT Dark Matter Experiment · 2024](https://arxiv.org/html/2402.10446v1)
- [XENONnT Analysis · 2024 preprint](https://arxiv.org/html/2409.08778v1)

## Related experiments and articles

How physics instruments measure · Reading path

### How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

1. [Article **Why a xenon detector needs liquid and gas**](https://sandboxphysics.com/stories/instruments/xenonnt-dual-phase-tpc/)

Fields & matter · Starter path

## From a field to an electron microscope

Map an electric field and steer a charged particle. Then find the electron's wavelength and use electron beams to see a crystal and a surface.

[Start here → **Make an Electric Field Visible** Move the probe around a dipole and check that the field always points downhill on the potential landscape. Observe · 8 min](https://sandboxphysics.com/labs/electric-field/)

1. [1 Make an Electric Field Visible](https://sandboxphysics.com/labs/electric-field/)
2. [2 A Charge Bending through Fields](https://sandboxphysics.com/labs/charged-particle/)
3. [3 Electron Wavelength & Voltage](https://sandboxphysics.com/labs/electron-wavelength/)
4. [4 Electron Diffraction & Reciprocal Space](https://sandboxphysics.com/labs/electron-diffraction/)
5. [5 TEM Bright Field, Dark Field & SAED](https://sandboxphysics.com/labs/tem-mode-selector/)
6. [6 SEM Secondary-Electron Topography](https://sandboxphysics.com/labs/sem-topography/)

[View the full path →](https://sandboxphysics.com/topics/fields-and-matter/#starter-path)